Skip to content

Heliasen Quality Control (WIP)

Description

Needs vertical and horizontal noise removal before been called.

1
2
3
    Checks light barrier image quality.

    Outputs main error and partial errors.

Real time: False

Usage

  • Feature extraction: Tools to extract features from a segmented image

Parameters

  • Activate tool (enabled): Toggle whether or not tool is active (default: 1)

Example

Source

Source image

Parameters/Code

Default values are not needed when calling function

1
2
3
4
5
6
7
from ipapi.ipt import call_ipt

call_ipt(
    ipt_id="IptHeliasenQualityControl",
    source="18HP01V22-CAM11-20180720081100.jpg",
    return_type="result"
)

Result image

Result image

Result data

key Value
hor_lines_removed 21
hor_pixels_removed 0
hor_lines_removed_hit_plant 8
expected_plant_top_position 251
vert_lines_removed 3
vert_pixels_removed 202
plant_top_position 251
horizontal_lines_hard_to_remove 0
final_plant_top_position 245
guide_only_pixels 1332
guide_average_pixels 5.620253164556962
guide_average_span 5.620253164556962
plant_bottom_error 0
leaning_error 0
hrz_error 3
guide_error 0
plant_top_error 0
error_level 3
report - Horizontal noise: Noise level critical (1 line per (46.75)), please clean sensor
report - Horizontal noise: 13 detected outside of plant, please clean sensor